00 The 10 Golden Rules
  1. Verify ABSoW matches PSoW. Count every installed unit. Flag discrepancies immediately.
  2. Photograph EVERY unit. Minimum 2 photos per installed unit unless otherwise noted. Wide + close-up.
  3. Include a reference object (tape measure, level, hand) for scale in at least one photo per product type.
  4. Capture labels and markings. Manufacturer stamps, model numbers, batch/lot IDs. If visible, photograph it.
  5. Measure spacing. Any product with "FT o.c." or "IN o.c." — tape measure between units, photo the tape.
  6. Shoot wide context first. Before close-ups, get a wide shot showing the overall installation area and its relation to the structure.
  7. Drive logs are MANDATORY for piers. Push, helical, and slab piers require drive logs — handwritten or digital. Cert will not generate without them.
  8. Clean lens, good lighting. Flash in crawlspaces. No blurry shots. Re-take if you can't read labels in the photo.
  9. Note deficiencies. Missing hardware, improper installation, structural concerns — document with photos AND written notes.
  10. Upload same day. Photos and logs submitted within 6 hours of site visit. Escalation triggers at T+6hr, T+24hr, T+48hr.
01 Underpinning Systems (UND)
UND-PUSH Push Pier SSI Drivelog
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per pier
Required Addon: Backfill (ADD-BKFL)
Default Spec Supportworks Pro PP288, 2.875" tube dia, 68,000 lbs capacity

Photos

#DescriptionRequirement
1Bracket & First Section — pier bracket secured to footing with first tube section visibleRequired — 1 per pier
2Final Depth / Completion — full pier assembly at final driven depthRequired — 1 per pier
3Pier Spacing (Wide Shot) — multiple piers along wall with tape measure for spacingRequired — 1 per wall run
4Manufacturer Label — close-up of stamps, model numbers, batch IDsIf visible

Measurements

Spacing (FT o.c.)Depth per pier (ft)Count vs PSoW

Checklist

Drive Log Fields
  • Pier number
  • Date driven
  • Number of tubes per pier
  • Total depth (ft)
  • PSI reading per tube section
  • Final PSI at refusal
  • Extension sleeve used (Y/N)
  • Rated capacity
UND-HELI Helical Pile SSI Drivelog
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per pier
Required Addon: Backfill (ADD-BKFL)
Default Spec Supportworks HP288, 8"-10"-12" triple helix, 2.875" shaft dia

Photos

#DescriptionRequirement
1Helical Head & Bracket — helix plates visible, connection hardware clearRequired — 1 per pier
2Final Installation — bracket, shaft, extension hardwareRequired — 1 per pier
3Spacing Wide Shot — tape measure for center-to-centerRequired — 1 per wall run
4Torque Reading / Equipment — torque readout if availableIf available

Measurements

Spacing (FT o.c.)Depth per pier (ft)Count vs PSoW

Checklist

Drive Log Fields
  • Pier number
  • Date installed
  • Helix configuration
  • Total depth (ft)
  • Torque readings at each 1-ft increment
  • Final torque at termination (ft-lbs)
  • Extension used (Y/N)
  • Rated capacity
UND-SLAB Slab Pier SSI Drivelog
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per pier
Required Addon: Slab Patch (ADD-SLAB)

Photos

#DescriptionRequirement
1Core Hole & Bracket — core hole with bracket on footingRequired — 1 per pier
2Final Pier Assembly — full pier at final depthRequired — 1 per pier
3Spacing (Wide) — multiple slab piers with spacingRequired — 1 per area

Measurements

Spacing (FT o.c.)Depth per pier (ft)Count vs PSoW

Checklist

Drive Log Fields
  • Pier number
  • Date driven
  • Number of tube sections
  • Total depth (ft)
  • PSI per section
  • Final PSI
  • Core hole diameter
  • Rated capacity
02 Anchor Systems (ANC)
ANC-WALL Wall Anchor SSI
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per anchor
Required Addon: Backfill (ADD-BKFL)
Default Spec 16x16 in interior plate, 12x12 in earth plate, 0.75" dia galvanized rod, 8-12 ft length

Photos

#DescriptionRequirement
1Interior Wall Plate — all 4 corner bolts and center nut visibleRequired — 1 per anchor
2Wide View — All Plates — all plates along wall with spacingRequired — 1 per wall
3Exterior Earth Anchor — before backfillIf accessible

Measurements

Spacing (FT o.c.)Count vs PSoW

Checklist

ANC-CHAN Channel Anchor SSI
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per anchor
Required Addon: Backfill (ADD-BKFL)

Photos

#DescriptionRequirement
1Channel Assembly on Wall — flush against wall, top and bottom anchoring visibleRequired — 1 per anchor
2Wide View of All Channels — all channels with spacingRequired — 1 per wall

Measurements

Spacing (FT o.c.)Count vs PSoW

Checklist

03 Bracing Systems (BRC)
BRC-CFRP CFRP Strap SSI
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per strap
Default Spec Fortress Stabilization, 12" width, 32,000 psi tensile, two-part epoxy

Photos

#DescriptionRequirement
1Individual Strap Close-up — full epoxy saturation, no bubblesRequired — 1 per strap
2Wide Wall View — all straps with spacingRequired — 1 per wall
3Termination Detail — top and bottom termination pointsRecommended

Checklist

BRC-STEEL Steel Brace / IntelliBrace SSI
Unit: Quantity (each) Spacing: FT o.c. Min Photos: 2 per brace
Default Spec W4x13 Steel I-Beam, floor & sill plate brackets, bolted connections

Photos

#DescriptionRequirement
1Full Brace Assembly — floor anchor to top connection, plumbRequired — 1 per brace
2Wide Wall View — all braces along wallRequired — 1 per wall
3Floor Anchor Detail — anchor bolt and base plateRecommended

Checklist

BRC-PIN Wall Pin
Unit: Quantity (each) Spacing: IN o.c. Min Photos: 2 per wall section
Default Spec Galvanized steel pin

Photos

#DescriptionRequirement
1Pin Heads Visible — pins in mortar joints with consistent spacingRequired — 1 per section
2Wide Wall View — full wall sectionRequired — 1 per wall

Checklist

04 Support Systems (SUP)
SUP-COL Adjustable Column / IntelliJack
Unit: Quantity (each) Min Photos: 2 per column
Default Spec Supportworks IntelliJack, 24,000 lbs load rating

Photos

#DescriptionRequirement
1Full Column Height — plumbRequired — 1 per column
2Top Bearing Contact — cap making positive contact with beam/floorRequired — 1 per column
3Base/Footer Connection — column base on footer padRequired — 1 per column

Checklist

SUP-SBM Steel Beam
Unit: Linear Feet (LF) Min Photos: 2 per beam

Photos

#DescriptionRequirement
1Full Beam Run — end to endRequired — 1 per beam
2Bearing Point Detail — each bearing pointRequired — 1 per end
3Beam Markings/Label — manufacturer markingsIf visible

Measurements

Length (LF)Beam section (e.g. W8x10)

Checklist

SUP-LBM Lumber Beam
Unit: Linear Feet (LF) Min Photos: 2 per beam

Photos

#DescriptionRequirement
1Full Beam Run — end to end with bearing pointsRequired — 1 per beam
2Bearing Point Detail — each end bearingRequired — 1 per end
3Grade Stamp — grade stamp and treatment markingIf visible

Checklist

SUP-FJ Floor Joist
Unit: Quantity (each) Spacing: IN o.c. Min Photos: 2 per area
Includes sistered joists. Note execution type (new, sister, repair).

Photos

#DescriptionRequirement
1Installed Joist — full length; for sistered, show bothRequired — 1 per joist/group
2Connection Detail — joist hanger, nailing, bearing connectionRequired — 1 per joist
3Wide Context — layout and spacingRequired — 1 per area

Checklist

SUP-RJ Rim Joist
Unit: Linear Feet (LF) Min Photos: 2 per section

Photos

#DescriptionRequirement
1Installed Rim Joist — fastening visibleRequired — 1 per section
2Connection to Sill/Floor — how it connects to sill plate and floor joistsRequired — 1 per section

Checklist

SUP-SP Sill Plate
Unit: Linear Feet (LF) Min Photos: 2 per section

Photos

#DescriptionRequirement
1Installed Sill Plate — on foundation wall with anchor boltsRequired — 1 per section
2Anchor Bolt Detail — spacing and washers/nutsRequired — 1 per section

Checklist

SUP-BB Band Board
Unit: Linear Feet (LF) Min Photos: 2 per section

Photos

#DescriptionRequirement
1Installed Band Board — fastening and adjacent framingRequired — 1 per section
2Connection Detail — nailing or boltingRecommended

Checklist

SUP-SF Subfloor
Unit: SF (square feet) Min Photos: 2 per area

Photos

#DescriptionRequirement
1Installed Subfloor — panels, fastening pattern, seam layoutRequired — 1 per area
2Fastening Detail — screw/nail pattern and adhesiveRecommended

Checklist

SUP-FCIP Pier Footer — Cast-in-Place
Unit: Quantity (each) Min Photos: 2 per footer

Photos

#DescriptionRequirement
1Footer with Column — column/post seated on footerRequired — 1 per footer
2Footer Dimensions — tape measure for dimensionsRequired — 1 per footer
3Excavation/Aggregate — excavation depth and aggregate before pourRecommended

Measurements

Dimensions (L x W)Aggregate depthConcrete thicknessCount vs PSoW

Checklist

SUP-FPRE Pier Footer — Precast
Unit: Quantity (each) Min Photos: 2 per footer

Photos

#DescriptionRequirement
1Footer with Column — precast footer with column/postRequired — 1 per footer
2Footer Dimensions — tape measureRequired — 1 per footer

Checklist

05 Foundation Systems (FND)
FND-WALL Foundation Wall
Unit: Linear Feet (LF) Min Photos: 2 per wall section

Photos

#DescriptionRequirement
1Wall Run — Wide — full wall run with dimensionsRequired
2Wall Thickness — thickness measurementRequired
3Rebar/Reinforcement — visible reinforcementIf accessible

Checklist

FND-FTR Continuous Footer
Unit: Linear Feet (LF) Min Photos: 2 per section

Photos

#DescriptionRequirement
1Footer in Trench — before backfillRequired
2Footer Dimensions — width and thickness with tapeRequired
3Rebar Layout — reinforcement before pourIf accessible

Checklist

FND-GSLAB Grade Slab
Unit: SF Min Photos: 2 per area

Photos

#DescriptionRequirement
1Full Slab View — complete slab-on-gradeRequired
2Thickness/Edge Detail — thickness at edge or control jointRequired
3Reinforcement/Mesh — wire mesh or rebar before pourIf accessible
4Control Joints — layout and spacingRecommended

Checklist

FND-SSLAB Structural Slab
Unit: SF Min Photos: 2 per area

Photos

#DescriptionRequirement
1Full Slab View — complete structural slabRequired
2Thickness Measurement — with tape measureRequired
3Rebar Layout (Pre-Pour) — rebar grid with spacingRequired if accessible

Checklist

FND-BKFL Foundation Backfill
Unit: CY or LF Min Photos: 1 per area

Photos

#DescriptionRequirement
1Completed Backfill — grade restored, sloped from foundationRequired
2Compaction — equipment/methodRecommended

Checklist

FND-PORCH Porch
Unit: SF/LF Min Photos: 2 per porch

Photos

#DescriptionRequirement
1Full Porch View — complete with building connectionRequired
2Footing/Support Detail — footings or support piersRequired
3Connection to Structure — ledger board, through-boltsRequired

Checklist

FND-STOOP Stoop
Unit: SF/LF Min Photos: 2 per stoop

Photos

#DescriptionRequirement
1Full Stoop View — stoop with steps and landingRequired
2Footing/Base — footing or base connectionRequired
3Railing — if above 30"If applicable

Checklist

FND-AREAWAY Areaway
Unit: LF/Each Min Photos: 2 per areaway

Photos

#DescriptionRequirement
1Full Areaway View — including walls and drainRequired
2Drain/Waterproofing — drain connection and waterproofingRequired
3Wall Connection — areaway to foundationRecommended

Checklist

FND-WTR Exterior Waterproofing
Unit: LF/SF Min Photos: 2 per section

Photos

#DescriptionRequirement
1Membrane Applied — on foundation wall before backfillRequired
2Drainage Board — over membraneRequired if in scope
3Footer Drain — perimeter drain at footer before backfillRequired if in scope

Checklist

FND-PIER Foundation Pier
Unit: Quantity (each) Min Photos: 2 per pier

Photos

#DescriptionRequirement
1Pier in Excavation — depth and diameterRequired — 1 per pier
2Reinforcement — rebar cage before pourRequired if in scope
3Connection to Footer — pier to footer/grade beamRequired — 1 per pier

Checklist

06 Water Management Systems (WTR)
WTR-BSMT Basement Water Management Parent
Unit: LF (drain) / Qty (pumps) Min Photos: 2 per component
Required Addons: Slab Patch (ADD-SLAB) + WallSeal (ADD-WSEAL)
Default Spec 1/3 HP pump, battery backup, sealed basin, check valve, PVC discharge 6+ ft

Photos

#DescriptionRequirement
1Drain Channel/Gutter — joint connections and slopeRequired
2Sump Pit & Pump — float switch and dischargeRequired
3Discharge Line — exit point 6+ ft from foundationRequired
4Wide System View — overall layoutRequired — 1 per area

Checklist

WTR-CRWL Crawlspace Water Management Parent
Unit: LF (drain) / Qty (pumps) Min Photos: 2 per component
Default Spec Sealed basin, PVC discharge, drain mat for crawlspace

Photos

#DescriptionRequirement
1Drain Tile Layout — USE FLASHRequired
2Sump Pit & Pump — float switch and connectionsRequired
3Exterior Discharge — discharge pointRequired

Checklist

07 Encapsulation Systems (ENC)
ENC-SYS Encapsulation System
Unit: SF/LF Min Photos: 2 per component
Default Spec 20-mil reinforced poly vapor barrier, pressure-sensitive tape, commercial dehumidifier with condensate routing

Photos

#DescriptionRequirement
1Full Encapsulation View — multiple angles, USE FLASHRequired — multiple
2Seam Detail — overlaps and tape jointsRequired
3Wall Attachment — barrier attachment to foundationRequired
4Dehumidifier — with drainage visibleRequired if in scope
5Rigid Insulation — panels on wallsRequired if in scope
6Pier/Column Wrapping — barrier around piers/columnsRecommended

Checklist

08 Retaining Wall Systems (RTW)
RTW-WALL Retaining Wall
Unit: Linear Feet (LF) Min Photos: 2 per wall

Photos

#DescriptionRequirement
1Full Wall Elevation — end to end with full heightRequired
2Wall Thickness/Section — construction and thicknessRequired
3Rebar/Reinforcement — before pour or visibleIf accessible

Checklist

RTW-FTR Retaining Wall Footing
Unit: LF Min Photos: 2 per section

Photos

#DescriptionRequirement
1Footing in Trench — rebar and dimensions visibleRequired
2Footing Dimensions — tape measure showing W x T x DRequired

Checklist

RTW-BKFL Retaining Wall Backfill
Unit: CY/LF Min Photos: 1 per area

Photos

#DescriptionRequirement
1Completed Backfill — proper grade behind wallRequired
2Drainage Aggregate — granular backfill against wallRecommended

Checklist

RTW-WTR Retaining Wall Waterproofing
Unit: LF/SF Min Photos: 2 per section

Photos

#DescriptionRequirement
1Waterproofing Membrane — on soil-facing side before backfillRequired
2Drainage System — drain tile and drainage boardRequired if in scope

Checklist

RTW-SOIL Soil Bearing
Unit: Each/Test Min Photos: 1 per test location

Photos

#DescriptionRequirement
1Bearing Surface — soil conditions at foundation levelRequired
2Test Equipment/Results — if availableIf available

Checklist

RTW-RAIL Railing
Unit: LF Min Photos: 2 per run

Photos

#DescriptionRequirement
1Full Railing Run — complete installationRequired
2Post Connection Detail — post to wall capRequired
3Height Measurement — tape measure, 42" code minRequired

Checklist

09 Addon Items (ADD)
ADD-BKFL Backfill Addon
Unit: Included with primary scope Min Photos: 1
Triggered by: UND-PUSH, UND-HELI, ANC-WALL, ANC-CHAN
Note: Anne Arundel County triggers Form 215

Photos

#DescriptionRequirement
1Completed Backfill — grade restored, sloped awayRequired when on SOW

Checklist

ADD-SLAB Slab Patch/Repair Addon
Unit: Included with primary scope Min Photos: 1
Triggered by: UND-SLAB, WTR-BSMT
Note: Anne Arundel County triggers Form 240

Photos

#DescriptionRequirement
1Completed Patch — flush with surrounding slabRequired when on SOW

Checklist

ADD-WSEAL WallSeal Addon
Unit: SF or LF Min Photos: 1
Triggered by: WTR-BSMT

Photos

#DescriptionRequirement
1Applied Membrane — coverage and adhesion visibleRequired when on SOW

Checklist